• Charges . The information received from the SHS (Scrap Handling System) is registered on the EAF IS, once the operator confirms a charge is done to the heat. This way, it's easy to know the layers composition of the scrap used in the charge.
• General Information . It consists on data such as: Grade of steel, Weight, electrical, electrode, and gas consumptions, temperatures, stages, shifts, and the crew assigned on each shift.
• Delays . It registers the periods of time in which the furnace is Turned Off during the Heat. Besides, it registers the causes of the delay.
• Events . This tool consists on a registration of all the events that occur during the heat. This is a very useful application that helps analyzing the rest of the registered data.
• Chemical Analysis . These are received from a wide variety of analyzing spectrum equipment.
• Life Data . It registers the periods of time and numbers of heats that have been done in certain parts of the machine, such as Delta, EAF Bottom, and Roof, with the purpose of reminding when they should be changed or repaired.
|